WSM3300
www.waynepumps.com
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
READ, UNDERSTAND AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL - DO NOT DISCARD.
Failure to follow these instructions could result in property damage, bodily injury or death.
Battery acid is corrosive. Avoid spilling on skin or
clothing. Eye protection MUST be worn when
handling the battery.
A check valve MUST be used on the primary
and back-up sump discharge.
A ground fault circuit interrupter is required.
This pump MUST only be used to pump clear
water. This pump is NOT designed to handle
effluent, salt water, brine, laundry discharge, or any other application
which MAY contain caustic chemicals and/or foreign materials. Pump
damage MAY occur if used in these applications and WILL void warranty.
SPECIFICATIONS
CONSTRUCTION
DESCRIPTION
The 12 Volt Advanced Notification System includes a DC back-
up sump pump, an electronic controller with digital display, and
an auto-dialer. Optimal back-up power is supplied by a 12 volt
battery (not included). The system is designed for home sump
applications. When an electrical power outage occurs, the
electronic controller automatically switches the sump pump to
battery power. Power loss will initiate a phone call via the auto-
dialer to the phone number(s) entered by the homeowner. With
a 24-hour monitor and a predetermined full system check, the
system tells you it’s status via a digital display and alerts you to
potential problems with an audible horn and phone call.
UNPACKING
Inspect this unit before it is used. Occasionally, products are
damaged during shipment. If the pump or components are
damaged, contact customer service at 1-800-237-0987.
SAFETY GUIDELINES
To help recognize this information, observe the following signal
words/hazard classifications.
This is the safety alert symbol. It is used to alert you to
potential bodily injury hazards. Obey all safety messages that
follow this symbol to avoid possible harm.
Danger indicates an imminently hazardous
situation which, if NOT avoided, WILL result
in death or serious injury.
Warning indicates a potentially hazardous
situation which, if NOT avoided, COULD
result in death or serious injury.
Caution indicates a potentially hazardous
situation which, if NOT avoided, MAY result
in minor or moderate injury.
Notice indicates important information, that if
NOT followed, MAY cause damage to equipment.
GENERAL SAFETY INFORMATION
This pump is NOT rated for use with flammable/
combustible liquids vapors or dusts.
Do NOT use to pump flammable/combustible liquids vapors
or dusts. Do NOT use in a flammable and/or explosive
atmosphere. Pump SHOULD be used to pump clear water
ONLY. Failure to follow these instructions WILL result in bodily
injury or death.
Electric shock hazard.
Disconnect
power before servicing. Apply a fixed
lock or tag to prevent unexpected application of power.
Electric shock hazard. DO NOT walk
on wet floor until power is disconnected. Use a
licensed electrician to perform service in accordance with the National
Electrical Code and all local codes.
© 2012, WAYNE/Scott Fetzer Company.
2
12 Volt Advanced
Notification System
OPERATING INSTRUCTIONS & PARTS MANUAL
CALIFORNIA PROPOSITION 65
This product or its power cord MAY contain
chemicals, including lead, known to the
State of California to cause cancer and birth defects or other
reproductive harm. Wash hands after handling.
Explosion hazard. Smoking and open flames
prohibited. Battery recharging and
connections MUST be performed in a well ventilated area
.
Power Supply Requirements ......120 V, 60 Hz
Motor ..........................................12 V DC Motor
Pump Dimensions ......................11 in. high x 8 3/4 in. base
Motor Housing ...........................
Impeller ......................................
Shaft ..........................................
Discharge ..................................
Float Switch ..............................
NEVER allow children to use pump.
Chemical hazard. If battery acid contacts
your eyes, immediately flush eyes with
copious amounts of clean, tepid water for at least 30 minutes. Seek
medical attention.
BATTERY INFORMATION
The system is designed to operate most efficiently
with a
deep cycle, sealed lead (Pb) acid (SLA) battery. A deep cycle
marine battery can also be used. Sealed lead acid batteries cost
slightly more, but they can last longer than a wet cell battery and
are maintenance free. The oversize battery case (included) will
accomodate one 12 Volt battery up to a 27-frame size. Use a new
battery. Chart 1 illustrates the expected performance with various
battery combinations. Do not use batteries rated below 40 amp
hours. Be certain that the area around the battery is well ventilated.
Before servicing the battery, blow away gasses by waving a piece
of cardboard near the battery. An assistant should be present or
close enough to come to your aid in the event of an emergency.
Have a reliable source of fresh water and soap nearby in case
battery acid contacts clothing, skin or eyes. Wear eye and clothing
protection when working around lead acid batteries. Avoid touching
your eyes when working around lead acid batteries.
Thermoplastic
Thermoplastic
Stainless Steel
1-1/2 in. NPT
Dual Reed
INSTALLATION AND OPERATING INSTRUCTIONS
Seitenansicht 1
1 2 3 4 5 6 7 ... 35 36

Kommentare zu diesen Handbüchern

Keine Kommentare

Extreme Networks Summit X450e Series podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Switche sieciowe Extreme Networks Summit X450e Series.
Dostarczamy 1 pdf podręczników Extreme Networks Summit X450e Series do pobrania za darmo według typów dokumentów: Instrukcja Użytkownika






Więcej produktów i instrukcji dla Switche sieciowe Extreme Networks

Modele Rodzaj dokumentu
Summit Summit48i Przewodnik Instalacji   Extreme Networks Summit Summit48i Installation guide [en] , 65 strony
BlackDiamond 6816 Dokumentacja   Extreme Networks BlackDiamond 6816 Specifications, 41 strony
BlackDiamond 6804 Instrukcja Użytkownika   TECH BRIEF - Arrow ECS, 6 strony
Altitude 4760 Series Instrukcja Użytkownika   Summit X650 Series Fixed Configuration Switches Data Sheet, 12 strony
BlackDiamond 12804 Instrukcja Użytkownika   BlackDiamond 12804C [en] , 9 strony
Summit Summit2 Przewodnik Instalacji   Extreme Networks Summit Summit2 Installation guide [en] , 46 strony
Summit 300-48 Instrukcja Użytkownika   data sheet - summit 300-24 unified access switch, 6 strony
Summit X440 Series Instrukcja Użytkownika   Extreme Networks - Danes Datennetzwerktechnik GmbH, 36 strony
Alpine 3802 Instrukcja Użytkownika   Alpine® 3800 Series Switches, 5 strony
Summit Summit4 Podręcznik Użytkownika   Extreme Networks Summit Summit4 User guide, 342 strony
Summit WM1000 Instrukcja Użytkownika   Summit® WM100 and Summit WM1000 4.0 Release, 6 strony
Summit X450a-48tDC Instrukcja Użytkownika   SummitX450a Series, 16 strony
MSM-3 Dokumentacja   Extreme Networks MSM-3 Specifications, 66 strony
Summit 200-48 Instrukcja Użytkownika   Summit® 200 Series - Andover Consulting Group, Inc., 6 strony
BlackDiamond 10808 Przewodnik Instalacji   Extreme Networks BlackDiamond 10808 Installation guide [en] [es] , 48 strony
Alpine 3800 FM-24MFi Dokumentacja   Extreme Networks Alpine 3800 FM-24MFi Specifications, 112 strony
Summit 300-48 Instrukcja Użytkownika   Summit® 300 Series Switches - Andover Consulting Group, Inc., 7 strony
Alpine 3800 FM-24MFi Przewodnik Instalacji   Extreme Networks Alpine 3800 FM-24MFi Installation guide [en] , 394 strony
Altitude 4760 Series Instrukcja Użytkownika   BlackDiamond 8800 Series Chassis, 13 strony
Summit WM1000 Instrukcja Użytkownika   Summit® WM100/Summit WM1000 Series, 8 strony