WAYNE COMBUSTION SYSTEMS
801 GLASGOW AVE.
FORT WAYNE, IN 46803
ELECTRIC SHOCK HAZARD
OVERHEATING HAZARD
HIGH VOLTAGES ARE PRESENT IN THIS EQUIPMENT.
FOLLOW THESE RULES TO AVOID ELECTRIC SHOCK.
Use only a properly grounded circuit. A ground fault
interrupter is recommended.
Do not spray water directly on burner.
Turn off power before servicing.
Read the owner’s manual before using.
SHOULD OVERHEATING OCCUR:
Shut off the manual gas valve to the appliance.
Do not
shut off the control switch to the pump or blower.
SPECIFICATIONS
FOR YOUR SAFETY
IF YOU SMELL GAS:
1. OPEN WINDOWS
2. DON’T TOUCH ELECTRICAL SWITCHES
3. EXTINGUISH ANY OPEN FLAME
4. IMMEDIATELY CALL YOUR GAS
SUPPLIER.
THESE INSTRUCTIONS SHOULD BE AFFIXED TO THE
BURNER OR ADJACENT TO THE HEATING APPLIANCE.
MODELS
P250AF P265
P250AF-EP P265F
P250AF-DI P265-EP
P265-EP
GAS BURNER
Publication Date 5/01 - Revision B - Manual 101220
NOTE: Dimensions in ( ) are informational only. English values take priority.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light the appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a qualified
installer, service agency or the gas supplier. Warranty is
voided if not installed by qualified service person.
CARBON MONOXIDE IS A COLORLESS, ODORLESS GAS
THAT CAN KILL. FOLLOW THESE RULES TO CONTROL
CARBON MONOXIDE.
Do not use this burner if in an unvented, enclosed area. Carbon
monoxide may accumulate.
Do not adjust the pressure regulator. High pressures produce
carbon monoxide.
Check flue gases for carbon monoxide. This check requires
specialized equipment.
Allow only qualified burner service persons to adjust the burner.
Special instruments and training are required.
Read the owner’s manual before using.
CARBON MONOXIDE
POISONING HAZARD
NOTICE
BURNER MODELS MINIMUM INPUT MAXIMUM INPUT FUELS
P-250AF & P-250AF-EP & P250AF-DI 50,000 BTU/HR (14.65 kW/Hr) 250,000 BTU/Hr (73.27 kW/Hr) Natural & L.P. Gas
P-265 & P-265-EP 65,000 BTU/HR (19.05 kW/Hr) 200,000 BTU/Hr (58.61 kW/Hr) Natural & L.P. Gas
P-265-F & P-265F-EP 65,000 BTU/HR (19.05 kW/Hr) 200,000 BTU/Hr (58.61 kW/Hr) Natural & L.P. Gas
ELECTRICAL Power Supply - 115V/60HZ 1 Ph. MOUNTING: Adjustable Flange is Standard
Pedestal Mount is Optional.
Seitenansicht 0
1 2 3 4 5 6 ... 24 25

Inhaltsverzeichnis

Seite 1 - SPECIFICATIONS

WAYNE COMBUSTION SYSTEMS801 GLASGOW AVE.FORT WAYNE, IN 46803ELECTRIC SHOCK HAZARDOVERHEATING HAZARDHIGH VOLTAGES ARE PRESENT IN THIS EQUIPMENT.FOLLOW

Seite 2

9ADJUSTMENT OF BURNERStarting the burner:1. Depress the gas valve control knob on the combination gas valve and turn to “OFF”. Figure 9.2. Set room th

Seite 3 - FLUE PIPE AND CHIMNEY

10P265DI - JUNCTION BOX ROTATEDP265DI

Seite 4 - FIGURE 4

11All adjustments below must be made with the following instructions:1. Draft Gauge 3. CO Tester2. O2or CO2Analyzer 4. Water Column GaugeAfter the bur

Seite 5

12GENERAL INSTRUCTIONGas burners require the services of an experienced technician for proper setting and adjustment. If the burner does notappear to

Seite 6

13P 265-EP, P265F-EP, P250AF-EPINTERMITTENT PILOT INSTRUCTIONFOR HONEYWELL SYSTEMSTARTING BURNER1. Depress the gas valve control knob on the combinat

Seite 7

14IMPORTANT: The electronic S8600 Control Module cannot be repaired. If troubleshooting procedure indicates a malfunction inthe S8600 the S8600 Contro

Seite 8

15S8600, S8610 TROUBLESHOOTING GUIDENOTE: Before troubleshooting, familiarize yourself with the start up and checkout procedure.Check line voltage po

Seite 9

16P250AF/P265-DIDIRECT SPARK IGNITIONHONEYWELL SYSTEMStarting the burner:1) Turn the gas valve control knob to “OFF”, wait five minutes.2) Turn gas

Seite 10 - COMBINATION GAS VALVE

17TROUBLESHOOTINGAlthough the following tests can be made using standard volt meter, it is quicker and more convenient to use a FenwalModel 05-125539

Seite 11 - P265DI - JUNCTION BOX ROTATED

18To measure flame current, first shut off the power to the system and then remove the flame sensing lead wire form theelectrode terminal and insert a

Seite 12 - FIG. A FIG. B

1These instructions were prepared for the guidance of those installing this particular gas conversion burner. While thy apply inprinciple to all inst

Seite 13

19P265P265FP265EPP265FEP1 Air Tube & Housing Assy. 5” (127mm) Burner 62715-001 • •1 Air Tube & Housing Assy. 8” (203.2mm) Burner 62715-003 • •

Seite 14

20P250AFP250AF-EPP250AF-DI1 Control Box Assembly 62296 • •1 Power Cord Assembly 60182-002 • •1 Transformer 60186-003 • •1 Relay 60187 • •1 Control Box

Seite 15 - SEQUENCE OF OPERATION

21PARTS LIST - P265/P265F SERIES GAS BURNERS62903-001 Control Box/Strap Assembly 1 • • • • •••••60182-002 Power Cord Assembly 1 • • •60186-004 Transfo

Seite 16

22PARTS LIST - P250AF SERIES GAS BURNERS62903-001 Control Box/Strap Assembly 1 • • •60182-002 Power Cord Assembly 1 •60186-004 Transformer-24V 1 • • •

Seite 17

23Notes

Seite 18

24 MSR & MSR-DC 22019-003 Rev. C 08/15/00LIMITED WARRANTIES FOR OIL AND GAS BURNERS, MADE BY WAYNE ANDUSED IN RESIDENTIAL INSTALLATIONSWAYNE COM

Seite 19

2FLUE PIPE AND CHIMNEYThe flue pipe should be carefully inspected and replaced if necessary in connection with installation of a draft hood. Allinsta

Seite 20

3FIGURE 2FIGURE 3FIGURE 41/2” (12.7 mm)Minimum rise 1/4” (6.35mm) to the foot (.305 m)Minimum rise 1/4” (6.35mm) to the foot (.305 m)Minimum rise 1/4”

Seite 21 - P250AF-DI

4PREPARATION OF FURNACE OR BOILERClean combustion chamber thoroughly. Scrape and brush all heating surfaces and flue ways. Soot and fly ash are exce

Seite 22

5COMBUSTION CHAMBERSThe combustion chamber sizes given in Figure 5 are based on the maximum rated BTU capacity. If the input is to bepermanently set

Seite 23 - P250AF P250AF EP P250AF DI

6NOTE: The BTU input valves on the preceding page show the approximate hourly input of the burner for the various drillsizes shown. To determine th

Seite 24

7ELECTRICAL WIRINGThe power burner is shipped completely wired. It is only necessary to supply the 115 volt circuit, thermostat and limit circuit.All

Seite 25 - WAYNE COMBUSTION SYSTEMS

8After the piping and meter have been checked completely, purge the system of air. Do not bleed the air inside the furnace.Be sure to relight all the